Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.013
Filtrar
1.
BMC Cardiovasc Disord ; 24(1): 203, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594610

RESUMO

BACKGROUND: In patients with hypertrophic cardiomyopathy (HCM), ischemic myocardial fibrosis assessed by late gadolinium enhancement (I-LGE) using cardiovascular magnetic resonance (CMR) have been reported. However, the clinical significance of I-LGE has not been completely understood. We aim to evaluate the I-LGE differ phenotypically from HCM without LGE or nonischemic myocardial fibrosis assessed by late gadolinium enhancement (NI-LGE) in the left ventricle (LV). METHODS: The patients with HCM whom was underwent CMR were enrolled, using cine cardiac magnetic resonance to evaluate LV function and LGE to detect the myocardial fibrosis. Three groups were assorted: 1) HCM without LGE; 2) HCM with LGE involved the subendocardial layer was defined as I-LGE; 3) HCM with LGE not involved the subendocardial layer was defined as NI-LGE. RESULTS: We enrolled 122 patients with HCM in the present study. LGE was detected in 58 of 122 (48%) patients with HCM, and 22 (18%) of patients reported I-LGE. HCM with I-LGE had increased higher left ventricular mass index (LVMI) (P < 0.0001) than HCM with NI-LGE or without LGE. In addition, HCM with I-LGE had a larger LV end- systolic volume (P = 0.045), lower LV ejection fraction (LVEF) (P = 0.026), higher LV myocardial mass (P < 0.001) and thicker LV wall (P < 0.001) more than HCM without LGE alone. The I-LGE were significantly associated with LVEF (OR: 0.961; P = 0.016), LV mass (OR: 1.028; P < 0.001), and maximal end-diastolic LVWT (OR: 1.567; P < 0.001). On multivariate analysis, LVEF (OR: 0.948; P = 0.013) and maximal end-diastolic LVWT (OR: 1.548; P = 0.001) were associated with higher risk for I-LGE compared to HCM without LGE. Noticeably, the maximal end-diastolic LVWT (OR: 1.316; P = 0.011) was the only associated with NI-LGE compared to HCM without LGE. CONCLUSIONS: I-LGE is not uncommon in patients with HCM. HCM with I-LGE was associated with significant LV hypertrophy, extensive LGE and poor LV ejection fraction. We should consider focal ischemic myocardial fibrosis when applying LGE to risk stratification for HCM.


Assuntos
Cardiomiopatia Hipertrófica , Meios de Contraste , Humanos , Gadolínio , Imagem Cinética por Ressonância Magnética , Cardiomiopatia Hipertrófica/diagnóstico , Miocárdio/patologia , Fibrose , Espectroscopia de Ressonância Magnética
2.
Circ Cardiovasc Imaging ; 17(4): e016415, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38563143

RESUMO

BACKGROUND: In heart transplant recipients, right ventricular (RV) dysfunction may occur for a variety of reasons. Whether RV dysfunction in the stable phase after heart transplantation is associated with long-term adverse outcomes is unknown. We aimed to determine the long-term prognostic significance of RV dysfunction identified on cardiovascular magnetic resonance imaging (CMR) at least 1 year after heart transplantation. METHODS: In consecutive heart transplant recipients who underwent CMR for surveillance, we assessed 2 CMR measures of RV function: RV ejection fraction and RV global longitudinal strain (RVGLS). We investigated associations between RV dysfunction and a composite end point of death or major adverse cardiac events, including retransplantation, nonfatal myocardial infarction, coronary revascularization, and heart failure hospitalization. RESULTS: A total of 257 heart transplant recipients (median age, 59 years; 75% men) who had CMR at a median of 4.3 years after heart transplantation were included. Over a median follow-up of 4.4 years after the CMR, 108 recipients experienced death or major adverse cardiac events. In a multivariable Cox regression analysis adjusted for age, time since transplantation, indication for transplantation, cardiac allograft vasculopathy, history of rejection, and CMR covariates, RV ejection fraction was not associated with the composite end point, but RVGLS was independently associated with the composite end point with a hazard ratio of 1.08 per 1% worsening in RVGLS ([95% CI, 1.00-1.17]; P=0.046). RVGLS provided incremental prognostic value over other variables in multivariable analyses. The association was replicated in subgroups of recipients with normal RV ejection fraction and recipients with late gadolinium enhancement imaging. A similar association was seen with a composite end point of cardiovascular death or major adverse cardiac events. CONCLUSIONS: CMR feature tracking-derived RVGLS assessed at least 1 year after heart transplantation was independently associated with the long-term risk of death or major adverse cardiac events. Future studies should investigate its role in guiding clinical decision-making in heart transplant recipients.


Assuntos
Transplante de Coração , Infarto do Miocárdio , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Imagem Cinética por Ressonância Magnética , Função Ventricular Direita , Meios de Contraste , Fatores de Risco , Valor Preditivo dos Testes , Gadolínio , Imageamento por Ressonância Magnética , Volume Sistólico , Transplante de Coração/efeitos adversos , Prognóstico , Função Ventricular Esquerda
3.
Clin Res Cardiol ; 113(5): 781-789, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38619578

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) provides information on morpho-functional abnormalities and myocardial tissue characterisation. Appropriate indications for CMR in athletes are uncertain. OBJECTIVE: To analyse the CMR performed at our Institute to evaluate variables associated with pathologic findings in a large cohort of athletes presenting with different clinical conditions. METHODS: All the CMR performed at our Institute in athletes aged > 14 years were recruited. CMR indications were investigated. CMR was categorised as "positive" or "negative" based on the presence of morphological and/or functional abnormalities and/or the presence of late gadolinium enhancement (excluding the right ventricular insertion point), fat infiltration, or oedema. Variables associated with "positive" CMR were explored. RESULTS: A total of 503 CMR were included in the analysis. "Negative" and "positive" CMR were 61% and 39%, respectively. Uncommon ventricular arrhythmias (VAs) were the most frequent indications for CMR, but the proportion of positive results was low (37%), and only polymorphic ventricular patterns were associated with positive CMR (p = 0.006). T-wave inversion at 12-lead ECG, particularly on lateral and inferolateral leads, was associated with positive CMR in 34% of athletes (p = 0.05). Echocardiography abnormalities resulted in a large proportion (58%) of positive CMR, mostly cardiomyopathies. CONCLUSION: CMR is more efficient in identifying a pathologic cardiac substrate in athletes in case of VAs (i.e., polymorphic beats), abnormal ECG repolarisation (negative T-waves in inferolateral leads), and borderline echocardiographic findings (LV hypertrophy, mildly depressed LV function). On the other hand, CMR is associated with a large proportion of negative results. Therefore, a careful clinical selection is needed to indicate CMR in athletes appropriately.


Assuntos
Cardiologia , Cardiomiopatias , Humanos , Meios de Contraste , Gadolínio , Arritmias Cardíacas , Atletas , Espectroscopia de Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Valor Preditivo dos Testes
4.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(3): 553-562, 2024 Mar 20.
Artigo em Chinês | MEDLINE | ID: mdl-38597447

RESUMO

OBJECTIVE: To assess the value of cardiac magnetic resonance (CMR) imaging for predicting adverse left ventricular remodeling in patients with ST-segment elevation myocardial infarction (STEMI). METHODS: We retrospectively analyzed the clinical data and serial CMR (cine and LGE sequences) images of 86 STEMI patients within 1 week and 5 months after percutaneous coronary intervention (PCI), including 25 patients with adverse LV remodeling and 61 without adverse LV remodeling, defined as an increase of left ventricular end-systolic volume (LVESV) over 15% at the second CMR compared to the initial CMR. The CMR images were analyzed for LV volume, infarct characteristics, and global and infarct zone myocardial function. The independent predictors of adverse LV remodeling following STEMI were analyzed using univariate and multivariate Logistic regression methods. RESULTS: The initial CMR showed no significant differences in LV volume or LV ejection fraction (LVEF) between the two groups, but the infarct mass and microvascular obstructive (MVO) mass were significantly greater in adverse LV remodeling group (P < 0.05). Myocardial injury and cardiac function of the patients recovered over time in both groups. At the second CMR, the patients with adverse LV remodeling showed a significantly lower LVEF, a larger left ventricular end-systolic volume index (LVESVI) and a greater extent of infarct mass (P < 0.001) with lower global peak strains and strain rates in the radial, circumferential, and longitudinal directions (P < 0.05), infarct zone peak strains in the 3 directions, and infarct zone peak radial and circumferential strain rates (P < 0.05). The independent predictors for adverse LV remodeling following STEMI included the extent of infarct mass (AUC=0.793, 95% CI: 0.693-0.873; cut-off value: 30.67%), radial diastolic peak strain rate (AUC=0.645, 95% CI: 0.534-0.745; cut-off value: 0.58%), and RAAS inhibitor (AUC= 0.699, 95% CI: 0.590-0.793). CONCLUSION: The extent of infarct mass, peak radial diastolic strain rate, and RAAS inhibitor are independent predictors of adverse LV remodeling following STEMI.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/patologia , Remodelação Ventricular , Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda , Imageamento por Ressonância Magnética , Volume Sistólico , Valor Preditivo dos Testes
5.
Circ Cardiovasc Imaging ; 17(4): e016042, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38563190

RESUMO

BACKGROUND: Assessing myocardial strain by cardiac magnetic resonance feature tracking (FT) has been found to be useful in patients with overt hypertrophic cardiomyopathy (HCM). Little is known, however, of its role in sarcomere gene mutation carriers without overt left ventricular hypertrophy (subclinical HCM). METHODS: Thirty-eight subclinical HCM subjects and 42 healthy volunteers were enrolled in this multicenter case-control study. They underwent a comprehensive cardiac magnetic resonance study. Two-dimensional global radial, circumferential, and longitudinal strain of the left ventricle (LV) were evaluated by FT analysis. RESULTS: The subclinical HCM sample was 41 (22-51) years old and 32% were men. FT analysis revealed a reduction in global radial strain (29±7.2 versus 47.9±7.4; P<0.0001), global circumferential strain (-17.3±2.6 -versus -20.8±7.4; P<0.0001) and global longitudinal strain (-16.9±2.4 versus -20.5±2.6; P<0.0001) in subclinical HCM compared with control subjects. The significant differences persisted when considering the 23 individuals free of all the structural and functional ECG and cardiac magnetic resonance abnormalities previously described. Receiver operating characteristic curve analyses showed that the differential diagnostic performances of FT in discriminating subclinical HCM from normal subjects were good to excellent (global radial strain with optimal cut-off value of 40.43%: AUC, 0.946 [95% CI, 0.93-1.00]; sensitivity 90.48%, specificity 94.44%; global circumferential strain with cut-off, -18.54%: AUC, 0.849 [95% CI, 0.76-0.94]; sensitivity, 88.10%; specificity, 72.22%; global longitudinal strain with cut-off, -19.06%: AUC, 0.843 [95% CI, 0.76-0.93]; sensitivity, 78.57%; specificity, 78.95%). Similar values were found for discriminating those subclinical HCM subjects without other phenotypic abnormalities from healthy volunteers (global radial strain with optimal cut-off 40.43%: AUC, 0.966 [95% CI, 0.92-1.00]; sensitivity, 90.48%; specificity, 95.45%; global circumferential strain with cut-off, -18.44%: AUC, 0.866 [95% CI, 0.76-0.96]; sensitivity, 92.86%; specificity, 77.27%; global longitudinal strain with cut-off, -17.32%: AUC, 0.838 [95% CI, 0.73-0.94]; sensitivity, 90.48%; specificity, 65.22%). CONCLUSIONS: Cardiac magnetic resonance FT-derived parameters are consistently lower in subclinical patients with HCM, and they could emerge as a good tool for discovering the disease during a preclinical phase.


Assuntos
Cardiomiopatia Hipertrófica , Sarcômeros , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Feminino , Estudos de Casos e Controles , Sarcômeros/genética , Sarcômeros/patologia , Imagem Cinética por Ressonância Magnética/métodos , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/patologia , Espectroscopia de Ressonância Magnética , Mutação
6.
BMC Cardiovasc Disord ; 24(1): 223, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658849

RESUMO

BACKGROUND: Long-term exposure to a high altitude environment with low pressure and low oxygen could cause abnormalities in the structure and function of the heart. Myocardial strain is a sensitive indicator for assessing myocardial dysfunction, monitoring myocardial strain is of great significance for the early diagnosis and treatment of high altitude heart-related diseases. This study applies cardiac magnetic resonance tissue tracking technology (CMR-TT) to evaluate the changes in left ventricular myocardial function and structure in rats in high altitude environment. METHODS: 6-week-old male rats were randomized into plateau hypoxia rats (plateau group, n = 21) as the experimental group and plain rats (plain group, n = 10) as the control group. plateau group rats were transported from Chengdu (altitude: 360 m), a city in a plateau located in southwestern China, to the Qinghai-Tibet Plateau (altitude: 3850 m), Yushu, China, and then fed for 12 weeks there, while plain group rats were fed in Chengdu(altitude: 360 m), China. Using 7.0 T cardiac magnetic resonance (CMR) to evaluate the left ventricular ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV), as well as myocardial strain parameters including the peak global longitudinal (GLS), radial (GRS), and circumferential strain (GCS). The rats were euthanized and a myocardial biopsy was obtained after the magnetic resonance imaging scan. RESULTS: The plateau rats showed more lower left ventricular GLS and GRS (P < 0.05) than the plain rats. However, there was no statistically significant difference in left ventricular EDV, ESV, SV, EF and GCS compared to the plain rats (P > 0.05). CONCLUSIONS: After 12 weeks of exposure to high altitude low-pressure hypoxia environment, the left ventricular global strain was partially decreased and myocardium is damaged, while the whole heart ejection fraction was still preserved, the myocardial strain was more sensitive than the ejection fraction in monitoring cardiac function.


Assuntos
Altitude , Volume Sistólico , Função Ventricular Esquerda , Animais , Masculino , Ratos Sprague-Dawley , Doença da Altitude/fisiopatologia , Doença da Altitude/diagnóstico por imagem , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Fatores de Tempo , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Ratos , Hipóxia/fisiopatologia
7.
Sci Rep ; 14(1): 8951, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637609

RESUMO

This study aims at identifying risk-related patterns of left ventricular contraction dynamics via novel volume transient characterization. A multicenter cohort of AMI survivors (n = 1021) who underwent Cardiac Magnetic Resonance (CMR) after infarction was considered for the study. The clinical endpoint was the 12-month rate of major adverse cardiac events (MACE, n = 73), consisting of all-cause death, reinfarction, and new congestive heart failure. Cardiac function was characterized from CMR in 3 potential directions: by (1) volume temporal transients (i.e. contraction dynamics); (2) feature tracking strain analysis (i.e. bulk tissue peak contraction); and (3) 3D shape analysis (i.e. 3D contraction morphology). A fully automated pipeline was developed to extract conventional and novel artificial-intelligence-derived metrics of cardiac contraction, and their relationship with MACE was investigated. Any of the 3 proposed directions demonstrated its additional prognostic value on top of established CMR indexes, myocardial injury markers, basic characteristics, and cardiovascular risk factors (P < 0.001). The combination of these 3 directions of enhancement towards a final CMR risk model improved MACE prediction by 13% compared to clinical baseline (0.774 (0.771-0.777) vs. 0.683 (0.681-0.685) cross-validated AUC, P < 0.001). The study evidences the contribution of the novel contraction characterization, enabled by a fully automated pipeline, to post-infarction assessment.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Função Ventricular Esquerda , Humanos , Volume Sistólico , Fatores de Risco , Medição de Risco , Prognóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/patologia , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética
8.
Front Endocrinol (Lausanne) ; 15: 1351197, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38586451

RESUMO

Background: Right cardiac chamber remodeling is widespread in patients with connective tissue disease (CTD). Serum uric acid (SUA) is considered a potential independent risk factor for cardiovascular disease, and elevated SUA levels are often observed in patients with CTD. The correlation between SUA levels and right cardiac chamber remodeling remains unclear. This study investigated the association of SUA with right cardiac chamber remodeling as assessed by cardiac magnetic resonance feature-tracking (CMR-FT) in CTD patients. Methods and results: In this cross-sectional study, a total of 104 CTD patients and 52 age- and sex-matched controls were consecutively recruited. All individuals underwent CMR imaging, and their SUA levels were recorded. The patients were divided into three subgroups based on the tertiles of SUA level in the present study. CMR-FT was used to evaluate the right atrial (RA) longitudinal strain and strain rate parameters as well as right ventricular (RV) global systolic peak strain and strain rate in longitudinal and circumferential directions for each subject. Univariable and multivariable linear regression analyses were used to explore the association of SUA with RV and RA strain parameters. Compared with the controls, the CTD patients showed significantly higher SUA levels but a lower RV global circumferential strain (GCS) and RA phasic strain parameters (all p < 0.05), except the RA booster strain rate. RV GCS remained impaired even in CTD patients with preserved RV ejection fraction. Among subgroups, the patients in the third tertile had significantly impaired RV longitudinal strain (GLS), RV GCS, and RA reservoir and conduit strain compared with those in the first tertile (all p < 0.05). The SUA levels were negatively correlated with RV GLS and RV GCS as well as with RA reservoir and conduit strain and strain rates (the absolute values of ß were 0.250 to 0.293, all P < 0.05). In the multivariable linear regression analysis, the SUA level was still an independent determinant of RA conduit strain (ß = -0.212, P = 0.035) and RV GCS (ß = 0.207, P = 0.019). Conclusion: SUA may be a potential risk factor of right cardiac chamber remodeling and is independently associated with impaired RA conduit strain and RV GCS in CTD patients.


Assuntos
Imagem Cinética por Ressonância Magnética , Ácido Úrico , Humanos , Estudos Transversais , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
9.
Cardiovasc Diabetol ; 23(1): 133, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654269

RESUMO

BACKGROUND: Metabolic syndrome (MetS) can increase the risk of morbidity and mortality of cardiovascular disease and obstructive coronary artery disease (OCAD), which usually have a poor prognosis. This study aimed to explore the impact of MetS on left ventricular (LV) deformation and function in OCAD patients and investigate the independent factors of impaired LV function and deformation. MATERIALS AND METHODS: A total of 121 patients with OCAD and 52 sex- and age-matched controls who underwent cardiac magnetic resonance scanning were enrolled in the study. All OCAD patients were divided into two groups: OCAD with MetS [OCAD(MetS+), n = 83] and OCAD without MetS [OCAD(MetS-), n = 38]. LV functional and global strain parameters were measured and compared among the three groups. Multivariable linear regression analyses were constructed to investigate the independent factors of LV impairment in OCAD patients. Logistic regression analysis and receiver operating characteristic (ROC) curve analysis were performed to test the prediction efficiency of MetS for LV impairment. RESULTS: From controls to the OCAD(MetS-) group to the OCAD(MetS+) group, LV mass (LVM) increased, and LV global function index (LVGFI) and LV global longitudinal peak strain (GLPS) decreased (all p < 0.05). Compared with the OCAD(MetS-) group, the LV GLPS declined significantly (p = 0.027), the LVM increased (p = 0.006), and the LVGFI decreased (p = 0.043) in the OCAD(MetS+) group. After adjustment for covariates in OCAD patients, MetS was an independent factor of decreased LV GLPS (ß = - 0.211, p = 0.002) and increased LVM (ß = 0.221, p = 0.003). The logistic multivariable regression analysis and ROC analysis showed that combined MetS improved the efficiency of predicting LV GLPS reduction (AUC = 0.88) and LVM (AUC = 0.89) increase. CONCLUSIONS: MetS aggravated the damage of LV deformation and function in OCAD patients and was independently associated with LV deformation and impaired LV strain. Additionally, MetS increased the prediction efficiency of increased LVM and decreased LV GLPS. Early detection and intervention of MetS in patients with OCAD is of great significance.


Assuntos
Síndrome Metabólica , Valor Preditivo dos Testes , Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Síndrome Metabólica/fisiopatologia , Síndrome Metabólica/complicações , Síndrome Metabólica/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Idoso , Estudos de Casos e Controles , Medição de Risco , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/complicações , Imagem Cinética por Ressonância Magnética , Fatores de Risco , Prognóstico , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/complicações
10.
Circ Cardiovasc Imaging ; 17(3): e016115, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38502734

RESUMO

BACKGROUND: Multimodality imaging is currently suggested for the noninvasive diagnosis of cardiac masses. The identification of cardiac masses' malignant nature is essential to guide proper treatment. We aimed to develop a cardiac magnetic resonance (CMR)-derived model including mass localization, morphology, and tissue characterization to predict malignancy (with histology as gold standard), to compare its accuracy versus the diagnostic echocardiographic mass score, and to evaluate its prognostic ability. METHODS: Observational cohort study of 167 consecutive patients undergoing comprehensive echocardiogram and CMR within 1-month time interval for suspected cardiac mass. A definitive diagnosis was achieved by histological examination or, in the case of cardiac thrombi, by histology or radiological resolution after adequate anticoagulation treatment. Logistic regression was performed to assess CMR-derived independent predictors of malignancy, which were included in a predictive model to derive the CMR mass score. Kaplan-Meier curves and Cox regression were used to investigate the prognostic ability of predictors. RESULTS: In CMR, mass morphological features (non-left localization, sessile, polylobate, inhomogeneity, infiltration, and pericardial effusion) and mass tissue characterization features (first-pass perfusion and heterogeneity enhancement) were independent predictors of malignancy. The CMR mass score (range, 0-8 and cutoff, ≥5), including sessile appearance, polylobate shape, infiltration, pericardial effusion, first-pass contrast perfusion, and heterogeneity enhancement, showed excellent accuracy in predicting malignancy (areas under the curve, 0.976 [95% CI, 0.96-0.99]), significantly higher than diagnostic echocardiographic mass score (areas under the curve, 0.932; P=0.040). The agreement between the diagnostic echocardiographic mass and CMR mass scores was good (κ=0.66). A CMR mass score of ≥5 predicted a higher risk of all-cause death (P<0.001; hazard ratio, 5.70) at follow-up. CONCLUSIONS: A CMR-derived model, including mass morphology and tissue characterization, showed excellent accuracy, superior to echocardiography, in predicting cardiac masses malignancy, with prognostic implications.


Assuntos
Neoplasias Cardíacas , Derrame Pericárdico , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Neoplasias Cardíacas/diagnóstico , Prognóstico , Espectroscopia de Ressonância Magnética
11.
Sci Rep ; 14(1): 7523, 2024 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553581

RESUMO

Myocardial scar (MS) and left ventricular ejection fraction (LVEF) are vital cardiovascular parameters, conventionally determined using cardiac magnetic resonance (CMR). However, given the high cost and limited availability of CMR in resource-constrained settings, electrocardiograms (ECGs) are a cost-effective alternative. We developed computer vision-based multi-task deep learning models to analyze 12-lead ECG 2D images, predicting MS and LVEF < 50%. Our dataset comprises 14,052 ECGs with clinical features, utilizing ground truth labels from CMR. Our top-performing model achieved AUC values of 0.838 (95% CI 0.812-0.862) for MS and 0.939 (95% CI 0.921-0.954) for LVEF < 50% classification, outperforming cardiologists. Moreover, MS predictions in a prevalence-specific test dataset recorded an AUC of 0.812 (95% CI 0.810-0.814). Extracted 1D signals from ECG images yielded inferior performance, compared to the 2D approach. In conclusion, our results demonstrate the potential of computer-based MS and LVEF < 50% classification from ECG scan images in clinical screening offering a cost-effective alternative to CMR.


Assuntos
Aprendizado Profundo , Função Ventricular Esquerda , Humanos , Volume Sistólico , Cicatriz/diagnóstico por imagem , Eletrocardiografia/métodos , Imagem Cinética por Ressonância Magnética
12.
Sci Rep ; 14(1): 7504, 2024 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553622

RESUMO

Diffuse myocardial fibrosis is associated with adverse outcomes in heart failure with preserved ejection fraction (HFpEF). Dual-energy CT (DECT) can noninvasively assess myocardial fibrosis by quantification of extracellular volume (ECV) fraction. This study evaluated the association between ECV measured by DECT and clinical outcomes in patients with HFpEF. 125 hospitalized HFpEF patients were enrolled in this retrospective cohort study. ECV was measured using DECT with late iodine enhancement. The composite endpoint was defined as HFpEF hospitalization and all-cause mortality during the follow-up. During the median follow-up of 10.4 months, 34 patients (27.20%) experienced the composite outcomes, including 5 deaths; and 29 HFpEF hospitalizations. The higher DECT-ECV group had higher rates of composite outcomes than the low ECV group (log-rank X2 = 6.818, P = 0.033). In multivariate Cox regression analysis, the ECV (HR 1.17, 95% CI 1.06-1.30, P = 0.001) and NT-pro BNP (HR 2.83, 95% CI 1.16-6.88, P = 0.022) were independent risk factors for the adverse outcomes. Myocardial ECV measured using DECT was an independent risk factor for adverse outcomes in patients with HFpEF.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/diagnóstico por imagem , Prognóstico , Volume Sistólico , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética , Fibrose , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda , Valor Preditivo dos Testes
13.
Math Biosci Eng ; 21(3): 3695-3712, 2024 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-38549302

RESUMO

The two-dimensional (2D) cine cardiovascular magnetic resonance (CMR) technique is the reference standard for assessing cardiac function. However, one challenge with 2D cine is that the acquisition time for the whole cine stack is long and requires multiple breath holds, which may not be feasible for pediatric or ill patients. Though single breath-hold multi-slice cine may address the issue, it can only acquire low-resolution images, and hence, affect the accuracy of cardiac function assessment. To address these challenges, a Ferumoxytol-enhanced, free breathing, isotropic high-resolution 3D cine technique was developed. The method produces high-contrast cine images with short acquisition times by using compressed sensing together with a manifold-based method for image denoising. This study included fifteen patients (9.1 $ \pm $ 5.6 yrs.) who were referred for clinical cardiovascular magnetic resonance imaging (MRI) with Ferumoxytol contrast and were prescribed the 3D cine sequence. The data was acquired on a 1.5T scanner. Statistical analysis shows that the manifold-based denoised 3D cine can accurately measure ventricular function with no significant differences when compared to the conventional 2D breath-hold (BH) cine. The multiplanar reconstructed images of the proposed 3D cine method are visually comparable to the golden standard 2D BH cine method in terms of clarity, contrast, and anatomical precision. The proposed method eliminated the need for breath holds, reduced scan times, enabled multiplanar reconstruction within an isotropic data set, and has the potential to be used as an effective tool to access cardiovascular conditions.


Assuntos
Óxido Ferroso-Férrico , Imagem Cinética por Ressonância Magnética , Humanos , Criança , Imagem Cinética por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Coração/diagnóstico por imagem , Respiração , Reprodutibilidade dos Testes
14.
Phys Med Biol ; 69(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38518378

RESUMO

Objective.In this study, we tackle the challenge of latency in magnetic resonance linear accelerator (MR-Linac) systems, which compromises target coverage accuracy in gated real-time radiotherapy. Our focus is on enhancing motion prediction precision in abdominal organs to address this issue. We developed a convolutional long short-term memory (convLSTM) model, utilizing 2D cine magnetic resonance (cine-MR) imaging for this purpose.Approach.Our model, featuring a sequence-to-one architecture with six input frames and one output frame, employs structural similarity index measure (SSIM) as loss function. Data was gathered from 17 cine-MRI datasets using the Philips Ingenia MR-sim system and an Elekta Unity MR-Linac equivalent sequence, focusing on regions of interest (ROIs) like the stomach, liver, pancreas, and kidney. The datasets varied in duration from 1 to 10 min.Main results.The study comprised three main phases: hyperparameter optimization, individual training, and transfer learning with or without fine-tuning. Hyperparameters were initially optimized to construct the most effective model. Then, the model was individually applied to each dataset to predict images four frames ahead (1.24-3.28 s). We evaluated the model's performance using metrics such as SSIM, normalized mean square error, normalized correlation coefficient, and peak signal-to-noise ratio, specifically for ROIs with target motion. The average SSIM values achieved were 0.54, 0.64, 0.77, and 0.66 for the stomach, liver, kidney, and pancreas, respectively. In the transfer learning phase with fine-tuning, the model showed improved SSIM values of 0.69 for the liver and 0.78 for the kidney, compared to 0.64 and 0.37 without fine-tuning.Significance. The study's significant contribution is demonstrating the convLSTM model's ability to accurately predict motion for multiple abdominal organs using a Unity-equivalent MR sequence. This advancement is key in mitigating latency issues in MR-Linac radiotherapy, potentially improving the precision and effectiveness of real-time treatment for abdominal cancers.


Assuntos
Neoplasias Abdominais , Imagem Cinética por Ressonância Magnética , Humanos , Movimento (Física) , Abdome/diagnóstico por imagem , Neoplasias Abdominais/radioterapia , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
15.
Med Image Anal ; 94: 103142, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38492252

RESUMO

Cardiac cine magnetic resonance imaging (MRI) is a commonly used clinical tool for evaluating cardiac function and morphology. However, its diagnostic accuracy may be compromised by the low spatial resolution. Current methods for cine MRI super-resolution reconstruction still have limitations. They typically rely on 3D convolutional neural networks or recurrent neural networks, which may not effectively capture long-range or non-local features due to their limited receptive fields. Optical flow estimators are also commonly used to align neighboring frames, which may cause information loss and inaccurate motion estimation. Additionally, pre-warping strategies may involve interpolation, leading to potential loss of texture details and complicated anatomical structures. To overcome these challenges, we propose a novel Spatial-Temporal Attention-Guided Dual-Path Network (STADNet) for cardiac cine MRI super-resolution. We utilize transformers to model long-range dependencies in cardiac cine MR images and design a cross-frame attention module in the location-aware spatial path, which enhances the spatial details of the current frame by using complementary information from neighboring frames. We also introduce a recurrent flow-enhanced attention module in the motion-aware temporal path that exploits the correlation between cine MRI frames and extracts the motion information of the heart. Experimental results demonstrate that STADNet outperforms SOTA approaches and has significant potential for clinical practice.


Assuntos
Coração , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Movimento (Física) , Redes Neurais de Computação , Imageamento por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos
16.
Clin Exp Rheumatol ; 42(2): 309-315, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38488096

RESUMO

OBJECTIVES: There is an increasing interest in knowing whether patients with antisynthetase syndrome (ASSD) may have silent myocardial interstitial involvement. Mapping techniques in cardiac magnetic resonance (CMR) can detect subclinical myocardial involvement. The purpose of this study was to identify alterations in multiparametric CMR in ASSD patients without overt cardiac involvement. METHODS: Patients diagnosed with ASSD underwent a CMR along with the standard clinical workup, investigation of specific and associated myositis antibodies, and high-resolution chest CT. The CMR protocol includes routine morphologic, functional, and late gadolinium enhancement sequences in standard cardiac planes, as well as native T1 and T2 mapping sequences and extracellular volume (ECV) calculation. RESULTS: Twenty-five patients were included in this study (56% women; median age 56.3 years). Three patients were considered in the acute phase at the time of inclusion. Eight patients (32%) showed pathological findings in CMR (6 stable disease, 2 acute phase). Elevated T1, T2 and ECV mapping values were found in 20% (5/25), 17% (4/25) and 24% (6/25) of the group, respectively. Two patients in the acute phase had increased values of both T2 and ECV. CONCLUSIONS: Subclinical myocardial involvement in ASSD is not rare (32%) although its clinical significance is uncertain. Myocardial oedema (T2) was the most frequent finding, followed by increased T1 and/or ECV values likely signalling interstitial fibrosis. Of note, patients in the acute phase showed elevated T2 values.


Assuntos
Meios de Contraste , Miosite , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Imagem Cinética por Ressonância Magnética/métodos , Fibrose , Gadolínio , Miocárdio/patologia , Miosite/diagnóstico por imagem , Miosite/patologia , Valor Preditivo dos Testes
17.
Eur J Radiol ; 174: 111386, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38447431

RESUMO

PURPOSE: Studies have shown the incremental value of strain imaging in various cardiac diseases. However, reproducibility and generalizability has remained an issue of concern. To overcome this, simplified algorithms such as rapid atrioventricular strains have been proposed. This multicenter study aimed to assess the reproducibility of rapid strains in a real-world setting and identify potential predictors for higher interobserver variation. METHODS: A total of 4 sites retrospectively identified 80 patients and 80 healthy controls who had undergone cardiac magnetic resonance imaging (CMR) at their respective centers using locally available scanners with respective field strengths and imaging protocols. Strain and volumetric parameters were measured at each site and then independently re-evaluated by a blinded core lab. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to assess inter-observer agreement. In addition, backward multiple linear regression analysis was performed to identify predictors for higher inter-observer variation. RESULTS: There was excellent agreement between sites in feature-tracking and rapid strain values (ICC ≥ 0.96). Bland-Altman plots showed no significant bias. Bi-atrial feature-tracking and rapid strains showed equally excellent agreement (ICC ≥ 0.96) but broader limits of agreement (≤18.0 % vs. ≤3.5 %). Regression analysis showed that higher field strength and lower temporal resolution (>30 ms) independently predicted reduced interobserver agreement for bi-atrial strain parameters (ß = 0.38, p = 0.02 for field strength and ß = 0.34, p = 0.02 for temporal resolution). CONCLUSION: Simplified rapid left ventricular and bi-atrial strain parameters can be reliably applied in a real-world multicenter setting. Due to the results of the regression analysis, a minimum temporal resolution of 30 ms is recommended when assessing atrial deformation.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Átrios do Coração , Variações Dependentes do Observador , Função Ventricular Esquerda
18.
Am Heart J ; 271: 148-155, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38430992

RESUMO

BACKGROUND: Mortality after ST-segment elevation myocardial infarction (STEMI) is increased in patients with hypertension. The mechanisms underlying this association are uncertain. We sought to investigate whether patients with STEMI and prior hypertension have greater microvascular obstruction (MVO) and infarct size (IS) compared with those without hypertension. METHODS: We pooled individual patient data from 7 randomized trials of patients with STEMI undergoing primary percutaneous coronary intervention (PCI) in whom cardiac magnetic resonance imaging was performed within 1 month after reperfusion. The associations between hypertension and MVO, IS, and mortality were assessed in multivariable adjusted models. RESULTS: Among 2174 patients (61.3 ± 12.6 years, 76% male), 1196 (55.0%) had hypertension. Patients with hypertension were older, more frequently diabetic and had more extensive coronary artery disease than those without hypertension. MVO and IS measured as percent LV mass were not significantly different in patients with and without hypertension (adjusted differences 0.1, 95% CI -0.3 to 0.6, P = .61 and -0.2, 95% CI -1.5 to 1.2, P = .80, respectively). Hypertension was associated with a higher unadjusted risk of 1-year death (hazard ratio [HR] 2.28, 95% CI 1.44-3.60, P < .001), but was not independently associated with higher mortality after multivariable adjustment (adjusted HR 1.04, 95% CI 0.60-1.79, P = .90). CONCLUSION: In this large-scale individual patient data pooled analysis, hypertension was not associated with larger IS or MVO after primary PCI for STEMI.


Assuntos
Hipertensão , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Intervenção Coronária Percutânea/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Hipertensão/complicações , Imagem Cinética por Ressonância Magnética/métodos , Idoso , Microcirculação , Imageamento por Ressonância Magnética/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
19.
Phys Med Biol ; 69(9)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38479004

RESUMO

Objective. 3D cine-magnetic resonance imaging (cine-MRI) can capture images of the human body volume with high spatial and temporal resolutions to study anatomical dynamics. However, the reconstruction of 3D cine-MRI is challenged by highly under-sampled k-space data in each dynamic (cine) frame, due to the slow speed of MR signal acquisition. We proposed a machine learning-based framework, spatial and temporal implicit neural representation learning (STINR-MR), for accurate 3D cine-MRI reconstruction from highly under-sampled data.Approach. STINR-MR used a joint reconstruction and deformable registration approach to achieve a high acceleration factor for cine volumetric imaging. It addressed the ill-posed spatiotemporal reconstruction problem by solving a reference-frame 3D MR image and a corresponding motion model that deforms the reference frame to each cine frame. The reference-frame 3D MR image was reconstructed as a spatial implicit neural representation (INR) network, which learns the mapping from input 3D spatial coordinates to corresponding MR values. The dynamic motion model was constructed via a temporal INR, as well as basis deformation vector fields (DVFs) extracted from prior/onboard 4D-MRIs using principal component analysis. The learned temporal INR encodes input time points and outputs corresponding weighting factors to combine the basis DVFs into time-resolved motion fields that represent cine-frame-specific dynamics. STINR-MR was evaluated using MR data simulated from the 4D extended cardiac-torso (XCAT) digital phantom, as well as two MR datasets acquired clinically from human subjects. Its reconstruction accuracy was also compared with that of the model-based non-rigid motion estimation method (MR-MOTUS) and a deep learning-based method (TEMPEST).Main results. STINR-MR can reconstruct 3D cine-MR images with high temporal (<100 ms) and spatial (3 mm) resolutions. Compared with MR-MOTUS and TEMPEST, STINR-MR consistently reconstructed images with better image quality and fewer artifacts and achieved superior tumor localization accuracy via the solved dynamic DVFs. For the XCAT study, STINR reconstructed the tumors to a mean ± SD center-of-mass error of 0.9 ± 0.4 mm, compared to 3.4 ± 1.0 mm of the MR-MOTUS method. The high-frame-rate reconstruction capability of STINR-MR allows different irregular motion patterns to be accurately captured.Significance. STINR-MR provides a lightweight and efficient framework for accurate 3D cine-MRI reconstruction. It is a 'one-shot' method that does not require external data for pre-training, allowing it to avoid generalizability issues typically encountered in deep learning-based methods.


Assuntos
Neoplasias , Respiração , Humanos , Imagem Cinética por Ressonância Magnética , Imageamento Tridimensional/métodos , Movimento (Física) , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
20.
Strahlenther Onkol ; 200(5): 418-424, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38488899

RESUMO

PURPOSE: This study aimed to assess the margin for the planning target volume (PTV) using the Van Herk formula. We then validated the proposed margin by real-time magnetic resonance imaging (MRI). METHODS: An analysis of cone-beam computed tomography (CBCT) data from early glottic cancer patients was performed to evaluate organ motion. Deformed clinical target volumes (CTV) after rigid registration were acquired using the Velocity program (Varian Medical Systems, Palo Alto, CA, USA). Systematic (Σ) and random errors (σ) were evaluated. The margin for the PTV was defined as 2.5 Σ + 0.7 σ according to the Van Herk formula. To validate this margin, we accrued healthy volunteers. Sagittal real-time cine MRI was conducted using the ViewRay system (ViewRay Inc., Oakwood Village, OH, USA). Within the obtained sagittal images, the vocal cord was delineated. The movement of the vocal cord was summed up and considered as the internal target volume (ITV). We then assessed the degree of overlap between the ITV and the PTV (vocal cord plus margins) by calculating the volume overlap ratio, represented as (ITV∩PTV)/ITV. RESULTS: CBCTs of 17 early glottic patients were analyzed. Σ and σ were 0.55 and 0.57 for left-right (LR), 0.70 and 0.60 for anterior-posterior (AP), and 1.84 and 1.04 for superior-inferior (SI), respectively. The calculated margin was 1.8 mm (LR), 2.2 mm (AP), and 5.3 mm (SI). Four healthy volunteers participated for validation. A margin of 3 mm (AP) and 5 mm (SI) was applied to the vocal cord as the PTV. The average volume overlap ratio between ITV and PTV was 0.92 (range 0.85-0.99) without swallowing and 0.77 (range 0.70-0.88) with swallowing. CONCLUSION: By evaluating organ motion by using CBCT, the margin was 1.8 (LR), 2.2 (AP), and 5.3 mm (SI). The margin acquired using CBCT fitted well in real-time cine MRI. Given that swallowing during radiotherapy can result in a substantial displacement, it is crucial to consider strategies aimed at minimizing swallowing and related motion.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Glote , Neoplasias Laríngeas , Imagem Cinética por Ressonância Magnética , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Imagem Cinética por Ressonância Magnética/métodos , Glote/diagnóstico por imagem , Masculino , Neoplasias Laríngeas/diagnóstico por imagem , Neoplasias Laríngeas/radioterapia , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Movimentos dos Órgãos , Sistemas Computacionais , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...